Delphi Connectors (Weather Pack)
|
Delphi Connectors (Weather Pack)
|
Special Tools
For equivalent regional tools, refer to
Special Tools
.
The following is the proper procedure for the repair of Weather PackĀ® Connectors.
1.
|
Separate the connector halves (1).
|
2.
|
Open the secondary lock. A secondary lock aids in terminal retention and is usually molded to the connector (1).
|
3.
|
Grasp the wire and push the terminal to the forward most position. Hold the wire in this position.
|
4.
|
Insert the Weather PackĀ® terminal removal tool EL-38125-10A into the front (mating end) of the connector cavity until it rests on the cavity shoulder (1).
|
5.
|
Gently pull on the wire to remove the terminal through the back of the connector (2).
Note
|
Never use force to remove a terminal from a connector.
|
|
7.
|
Reform the lock tang (2) and reset terminal in connector body.
|
8.
|
Close secondary locks and join connector halves.
|
9.
|
Verify that circuit is complete and working satisfactorily.
|
10.
|
Perform system check.
|
2.
|
Find the appropriate terminated lead.
|
3.
|
Use the appropriate splice sleeves depending on the gauge size.
|