Crankshaft Balancer Installation
Crankshaft Balancer Installation |
Special Tools
• |
EN 41998-B
Crankshaft Balancer Installer
|
• |
EN-45059
Angle Meter
|
• |
EN 46106
Flywheel Holding Tool
|
For equivalent regional tools, refer to Special Tools .
1. |
The
EN 46106
tool must be installed onto the flywheel.
|
2. |
Use the
EN 41998-B
installer , nut, bearing and washer to install the crankshaft balancer.
|
4. |
Place the crankshaft balancer in position on the crankshaft.
|
5. |
Thread the
EN 41998-B
installer in the crankshaft. Ensure you engage at least 10 threads of the
EN 41998-B
installer before pressing the crankshaft balancer in place.
|
6. |
Push the crankshaft balancer into position by tightening the nut on the
J 41998-B
installer until the large washer bottoms out on the crankshaft end.
|
7. |
Remove the
EN 41998-B
installer.
|
8. |
Install the NEW crankshaft balancer bolt.
|
9. |
Refer to
Fastener Caution
.
Tighten the crankshaft balancer bolt. |
9.1. |
Tighten the crankshaft balancer bolt to
100 Nm (74 lb ft)
.
|
9.2. |
Tighten the crankshaft balancer bolt an additional
150 degrees
using the
EN 45059
meter.
|
10. |
Remove the
EN 46106
tool.
|