SAAB WIS ONLINE

DTC P018B-P018D

DTC P018B-P018D

Diagnostic Instructions


Perform the Diagnostic System Check - Vehicle prior to using this diagnostic procedure.

Review Strategy Based Diagnosis for an overview of the diagnostic approach.

Diagnostic Procedure Instructions provides an overview of each diagnostic category.


DTC Descriptors

DTC P018B

Fuel Pressure Sensor Performance

DTC P018C

Fuel Pressure Sensor Circuit Low Voltage

DTC P018D

Fuel Pressure Sensor Circuit High Voltage

Diagnostic Fault Information

Circuit Short to Ground Open/High Resistance Short to Voltage Signal Performance
5 V Reference

P0641

P0641, P06A6

P0641

P06A6

Signal

P018C

P018B, P018C

P018D

P018B

Low Reference

-

P0641, P06A6

-

P06A6



Circuit/System Description

The fuel pressure sensor is located on the fuel line. The fuel pressure sensor monitors the fuel pressure in the fuel line. The fuel pump control module monitors the voltage signal from the fuel pressure sensor.

Conditions for Running the DTC


The engine is running.

DTC P018C, P018D, P0231, P0232, P023F, P064A, P1255 or P06A6 are not active.

DTC P0641 has not failed this ignition cycle.

Fuel pump control is enabled and the fuel pump control state is normal.

The engine has been running for at least 5 seconds.


Conditions for Setting the DTC

The fuel pump control module does not detect a change in the fuel pressure of at least 30 kPa (4.4 psi) when the fuel pump is operating. The fuel pressure sensor performance diagnostic provides a means to detect fuel pressure sensor output that is stuck within the normal operating range of the sensor.

Action Taken When the DTC Sets

DTC P018B, P018C and P018D are Type A DTCs.

Conditions for Clearing the DTC

DTC P018B, P018C and P018D are Type A DTCs.

Diagnostic Aids

Using the Failure Records data may help locate an intermittent condition. If you cannot duplicate the DTC, the information in the Failure Records can help determine how many miles since the DTC set. The Fail Counter and Pass Counter can help determine how many ignition cycles that the diagnostic test reported a pass and/or a fail.

Reference Information

Schematic Reference

Engine Controls Schematics

Connector End View Reference

Component Connector End Views

Description and Operation

Fuel System Description

Electrical Information Reference


Circuit Testing

Testing for Intermittent Conditions and Poor Connections

Connector Repairs

Wiring Repairs


DTC Type Reference

Powertrain Diagnostic Trouble Code (DTC) Type Definitions

Scan Tool Reference

Control Module References for scan tool information

Circuit/System Testing

Note

Verify that the fuel tank is not empty. Only perform this diagnostic if there is at least 2 gallons of fuel in the fuel tank. Clear the DTC, and start and run the engine. Verify that the DTC P018B resets before proceeding with the circuit system testing. If the DTC does not reset, refer to diagnostic aids.



1. Ignition OFF, disconnect the harness connector at the B47 fuel pressure sensor.

2. Ignition OFF, test for less than 1 Ω between the low reference circuit terminal 2 and ground.

3. If greater than the specified range, test the low reference circuit for an open/high resistance. If the circuit tests normal, replace the K27 fuel pump flow control module.

4. Ignition ON, test for 4.8-5.2 V between the B47 fuel pressure sensor 5 V reference circuit terminal 3 and ground.

5. If less than the specified range, test the 5 V reference circuit for a short to ground or an open/high resistance. If the circuit tests normal, replace the K27 fuel pump flow control module.

6. If greater than the specified range, test the 5 V reference circuit for a short to voltage. If the circuit tests normal, replace the K27 fuel pump flow control module.

7. Verify the scan tool 5 V reference 1 is less than 1 V.

8. If greater than the specified value, test the signal circuit terminal 1 for a short to voltage. If the circuit tests normal, replace the K27 fuel pump flow control module.

9. Install a 3 A fused jumper wire between the signal circuit terminal 1 and the 5 V reference circuit terminal 3. Verify the scan tool 5 V reference is greater than 4.8 V.

10. If less than the specified range, test the signal circuit for a short to ground or an open/high resistance. If the circuit tests normal, replace the K27 fuel pump flow control module.

11. If all circuits test normal, replace the B47 fuel pressure sensor.


Repair Instructions

Perform the Diagnostic Repair Verification after completing the diagnostic procedure.


Fuel Injection Fuel Rail Fuel Pressure Sensor Replacement

Control Module References for fuel pump control module replacement, setup, and programming