Engine Cranks Slowly
| Engine Cranks Slowly | 
| Diagnostic Instructions | 
| • | Perform the
        
         Diagnostic System Check - Vehicle
        
        prior to using this diagnostic procedure. | |
| • | Review
        
         Strategy Based Diagnosis
        
        for an overview of the diagnostic approach. | |
| • | Diagnostic Procedure Instructions
        
        provides an overview of each diagnostic category. | |
| Reference Information | 
Schematic Reference
Starting and Charging Schematics
Connector End View Reference
Component Connector End Views
Description and Operation
Starting System Description and Operation
Electrical Information Reference
| • | Circuit Testing | |
| • | Connector Repairs | |
| • | Testing for Intermittent Conditions and Poor Connections | |
| • | Wiring Repairs | |
Scan Tool Reference
Control Module References for scan tool information
| Circuit/System Verification | 
| 1. | Ignition OFF, measure and record the battery voltage at the C1 terminals. The voltage should be between 12.0-15.0 V. | |
| 2. | If not within the specified range, refer to
        
         Battery Inspection/Test
        
        . | |
| 3. | Remove the drive belts. Refer to one of the following: | |
| • | Drive Belt Replacement
        
        for the 2.0L engine | 
| • | Drive Belt Tensioner Replacement
        
        for the 2.0L engine | 
| • | Drive Belt Replacement
        
        for the 2.0L (Diesel) engine | 
| • | Drive Belt Tensioner Replacement
        
        for the 2.0L (Diesel) engine | 
| • | Drive Belt Tensioner Replacement
        
        for the 2.8L, 3.0L, 3.2L, or 3.6L engine | 
| • | Drive Belt Replacement
        
        for the 2.8L, 3.0L, 3.2L, or 3.6L engine | 
| 4. | Ignition ON, attempt to start the engine. Make sure the crankshaft is rotating normally. | |
| 5. | If the engine cranks normal, inspect the engine and belt drive system for mechanical binding, seized engine, or seized generator. | |
| 6. | Verify that a test lamp illuminates between the M64 starter motor B+ terminal A X2 and ground. | |
| 7. | If the test lamp does not illuminate, test the B+ circuit for a short to ground or an open/high resistance. | |
| 8. | Test for less than 0.5 V between the positive battery cable and terminal A X2 at the M64 starter motor as ignition is switched to start position. | |
| 9. | If greater than the specified value, replace the positive battery cable. | |
| 10. | Test for less than 0.5 V between the negative battery cable and the M64 Starter Motor case as ignition is switched to start position. | |
| 11. | If greater than the specified value, replace the negative battery cable. | |
| 12. | If all circuits test normal, replace the M64 Starter Motor. | |
| Repair Instructions | 
Perform the Diagnostic Repair Verification after completing the diagnostic procedure.
| • | Battery Positive Cable Replacement | |
| • | Battery Negative Cable Replacement (Gasoline) | |
| • | Starter Replacement (2.0L Diesel)
        
        
         Starter Replacement (LAU/A28NER)
        
        
         Starter Replacement (LDE/A16XER, LLU/A16LET, 2H0/A18XER)
        
        
         Starter Replacement (LHU/A20NFT) | |

 
		