Testing for Electrical Intermittents
 
  
 
 
  
   
    
     |  | Testing for Electrical Intermittents | 
   
  
  
   
   
    
    
    
    
    
   
   
    
    
     Special Tools
    
   
   
    J 39200 Digital Multimeter
    
    
    
    
    
    
    
   
   
    
   
   
    Perform the following procedures while wiggling the harness from side to side. Continue this at convenient points (about 6 inches apart) while watching the test equipment.
    
    
   
   
   
    
   
   
    
   
   
    
   
   
   
    If the fault is not identified, perform the procedure below using the MIN MAX feature on the J 39200 DMM. This feature allows you to manipulate the circuit without having to watch the J 39200. The J 39200 will generate an audible tone when a change is detected.
    
    
   
   
    
     
      
       | Note | 
      
       | 
         J 39200 must be used in order to perform the following procedure since it can monitor current, resistance or voltage while recording the minimum (MIN) and maximum (MAX) values measured.
         | 
     
    
    
   
   
   
    
     
      
       | 1. | Connect the J 39200 to both sides of a suspected connector (still connected), or from one end of a suspected circuit to the other. Refer to
        
         Troubleshooting with a Digital Multimeter
        
        for information on connecting the J 39200 to the circuit. 
 
 | 
     
    
   
   
    
     
      
       | 2. | Set the rotary dial of the J 39200 to the V (AC) or V (DC) position. 
 
 | 
     
    
   
   
    
     
      
       | 3. | Press the range button of the J 39200 in order to select the desired voltage range. 
 
 | 
     
    
   
   
    
     
      
       | 4. | Press the MIN MAX button of the J 39200. The J 39200 displays 100 ms RECORD and emits an audible tone (beep). 
 
 
          
           
            | Note |  
            | 
              The 100 ms RECORD mode is the length of time an input must stay at a new value in order to record the full change.
              |  
 | 
     
    
   
   
    
     
      
       | 5. | Simulate the condition that is potentially causing the intermittent connection, either by wiggling the connections or the wiring, test driving, or performing other operations. Refer to
        
         Inducing Intermittent Fault Conditions
        
        . 
 
 | 
     
    
   
   
    
     
      
       | 6. | Listen for the audible Min Max Alert which indicates that a new minimum or maximum value has been recorded. 
 
 | 
     
    
   
   
    
     
      
       | 7. | Press the MIN MAX button once in order to display the MAX value and note the value. 
 
 | 
     
    
   
   
    
     
      
       | 8. | Press the MIN MAX button again in order to display the MIN value and note the value. 
 
 | 
     
    
   
   
    
     
      
       | 9. | Determine the difference between the MIN and MAX values. 
 
 | 
     
    
   
   
    
     
      
       |  | • | If the variation between the recorded MIN and MAX voltage values is 1 V or greater an intermittent open or high resistance condition exists. Repair the condition as necessary. 
 
 | 
     
    
   
   
    
     
      
       |  | • | If the variation between the recorded MIN and MAX voltage values is less than 1 V, an intermittent open or high resistance condition does not exist. 
 
 |