SAAB WIS ONLINE

DTC table, ACC

DTC table, ACC

Fault code

Faulty function/component

ISAT display text

Action, see page

B1343

Solar sensor Open circuit or shorted to battery positive

FAULT X P/I B1343 SUN SENSOR OPEN CIRCUIT



B1347

Blended-air sensor Shorted to ground

FAULT X P/I B1347 MIXED AIR SENSOR SHORTED TO GROUND



B1348

Blended-air sensor Open circuit or shorted to battery positive

FAULT X P/I B1348 MIXED AIR SENSOR OPEN CIRCUIT



B1352

Cabin temperature sensor Shorted to ground

FAULT X P/I B1352 INT. TEMP SENSOR SHORTED TO GROUND



B1353

Cabin temperature sensor Open circuit or shorted to battery positive

FAULT X P/I B1353 INT. TEMP SENSOR OPEN CIRCUIT



B1355

Power for ventilation fan motor and cabin temperature sensor Shorted to ground

FAULT X P/I B1355 + TO FAN CONTR. UNIT AND INT. TEMP SENSOR SHORTED TO GROUND



B1360

Keypad faulty

FAULT X P/I B1360 KEYBOARD FAULT



B1493

A/C system Shorted to ground

FAULT X P/I B1493 A/C (TO ICE) SHORTED TO GROUND



B1498

Electrically heated rear window, shorted to ground

FAULT X P/I B1498 HEATED REAR WINDOW SHORTED TO GROUND



B1515

Common sensor ground shorted to battery positive

FAULT X P/I B1515 COMMON SENSOR GROUND SHORTED TO BATT+



B1605

Control module Internal control module fault

FAULT X P/I B1605 CONTROL MODULE FAULT



B1675

Air distribution flap motor Driver stage faulty

FAULT X P/I B1675 DRIVER STAGE DISTR. FLAP MOTOR



B1676

Recirculation flap motor Driver stage faulty

FAULT X P/I B1676 DRIVER STAGE RECIRC. FLAP MOTOR



B1677

Heater flap motor Driver stage faulty

FAULT X P/I B1677 DRIVER STAGE HEATER FLAP MOTOR





*) Not implemented in ACC M94.



Fault code

Faulty function/component

ISAT display text

Action, see page

B2402

Stepping motor for air distribution damper Shorted to ground

FAULT X P/I B2402 AIR DISTR. MOTOR SHORTED TO GROUND



B2403

Stepping motor for air distribution damper Open circuit

FAULT X P/I B2403 AIR DISTR. MOTOR OPEN CIRCUIT



B2404

Stepping motor for air distribution damper Shorting between connections or to battery positive

FAULT X P/I B2404 AIR DISTR. MOTOR SHORTING BETWEEN CONNECTIONS



B2405

Air distribution damper loose

FAULT X P/I B2405 AIR DISTRIBUTION FLAP LOOSE

*

B2406

Air distribution damper jammed

FAULT X P/I B2406 AIR DISTRIBUTION FLAP JAMMED

*

B2413

Motor for recirculation damper Open circuit

FAULT X P/I B2413 RECIRC. FLAP MOTOR OPEN CIRCUIT



B2414

Motor for recirculation damper Short circuited

FAULT X P/I B2414 RECIRC. FLAP MOTOR SHORT CIRCUIT



B2422

Fan test voltage Shorted to ground

FAULT X P/I B2422 FAN TEST VOLTAGE SHORTED TO GROUND

*

B2423

Fan test voltage Shorted to battery positive

FAULT X P/I B2423 FAN TEST VOLTAGE SHORTED TO B+

*

B2426

Fan control voltage Overload

FAULT X P/I B2426 FAN CONTROL VOLTAGE FAULTY



B2427

Fan control voltage Shorted to ground

FAULT X P/I B2427 FAN CONTROL VOLTAGE SHORTED TO GROUND



B2428

Fan control voltage Shorted to battery positive

FAULT X P/I B2428 FAN CONTROL VOLTAGE SHORTED TO B+





*) Not implemented in ACC M94.



Fault code

Faulty function/component

ISAT display text

Action, see page

B2492

Stepping motor for air blending flap Shorted to ground

FAULT X P/I B2492 HEATER FLAP MOTOR SHORTED TO GROUND



B2493

Stepping motor for air blending damper Open circuit

FAULT X P/I B2493 HEATER FLAP MOTOR OPEN CIRCUIT



B2494

Stepping motor for air blending damper Shorting between connections

FAULT X P/I B2494 HEATER FLAP MOTOR SHORTING BETWEEN CONNECTIONS



B2495

Air blending damper loose

FAULT X P/I B2495 HEATER FLAP MOTOR FLAP LOOSE

*

B2496

Air blending damper jammed

FAULT X P/I B2496 HEATER FLAP MOTOR FLAP JAMMED

*



*) Not implemented in ACC M94.