Fault code
|
Faulty function/component
|
ISAT display text
|
Action, see page
|
B1343
|
Solar sensor Open circuit or shorted to battery positive
|
FAULT X P/I B1343 SUN SENSOR OPEN CIRCUIT
|
|
B1347
|
Blended-air sensor Shorted to ground
|
FAULT X P/I B1347 MIXED AIR SENSOR SHORTED TO GROUND
|
|
B1348
|
Blended-air sensor Open circuit or shorted to battery positive
|
FAULT X P/I B1348 MIXED AIR SENSOR OPEN CIRCUIT
|
|
B1352
|
Cabin temperature sensor Shorted to ground
|
FAULT X P/I B1352 INT. TEMP SENSOR SHORTED TO GROUND
|
|
B1353
|
Cabin temperature sensor Open circuit or shorted to battery positive
|
FAULT X P/I B1353 INT. TEMP SENSOR OPEN CIRCUIT
|
|
B1355
|
Power for ventilation fan motor and cabin temperature sensor Shorted to ground
|
FAULT X P/I B1355 + TO FAN CONTR. UNIT AND INT. TEMP SENSOR SHORTED TO GROUND
|
|
B1360
|
Keypad faulty
|
FAULT X P/I B1360 KEYBOARD FAULT
|
|
B1493
|
A/C system Shorted to ground
|
FAULT X P/I B1493 A/C (TO ICE) SHORTED TO GROUND
|
|
B1498
|
Electrically heated rear window, shorted to ground
|
FAULT X P/I B1498 HEATED REAR WINDOW SHORTED TO GROUND
|
|
B1515
|
Common sensor ground shorted to battery positive
|
FAULT X P/I B1515 COMMON SENSOR GROUND SHORTED TO BATT+
|
|
B1605
|
Control module Internal control module fault
|
FAULT X P/I B1605 CONTROL MODULE FAULT
|
|
B1675
|
Air distribution flap motor Driver stage faulty
|
FAULT X P/I B1675 DRIVER STAGE DISTR. FLAP MOTOR
|
|
B1676
|
Recirculation flap motor Driver stage faulty
|
FAULT X P/I B1676 DRIVER STAGE RECIRC. FLAP MOTOR
|
|
B1677
|
Heater flap motor Driver stage faulty
|
FAULT X P/I B1677 DRIVER STAGE HEATER FLAP MOTOR
|
|