DTC P0692 COOLING FAN 1 CONTROL CIRCUIT HIGH
DTC P0692 COOLING FAN 1 CONTROL CIRCUIT HIGH |
DTC DETECTING CONDITION:
• |
Two consecutive driving cycles with fault
|
• |
GENERAL DESCRIPTION
![]() |
TROUBLE SYMPTOM:
• |
Radiator fan does not operate properly.
|
• |
Overheating
|
Important | ||
After repair
or replacement of faulty parts, conduct Clear Memory Mode
|
||
WIRING DIAGRAM:

CHECK OUTPUT SIGNAL FROM ECM.
Turn the ignition switch to OFF.Connect the test mode connector.
Turn the ignition switch to ON.
While operating the radiator fan relay, measure the voltage between ECM and chassis ground.
Note | ||
Radiator fan relay operation can
be executed using the Vehicle Diagnostic
Interface. For procedure, refer to “Compulsory Valve Operation
Check Mode”.
|
Connector & terminal
(B84) No. 17 (+) — Chassis ground (−):
(B84) No. 28 (+) — Chassis ground (−):
Does the voltage change 0 — 10 V?
Yes |
Even if malfunction indicator light lights up, the circuit has returned to a normal condition at this time. In this case, repair the poor contact in ECM connector.
No |
CHECK SHORT CIRCUIT IN RADIATOR FAN RELAY CONTROL CIRCUIT.
Turn the ignition switch to OFF.Remove the fan relay 1, fan relay 2 and fan mode relay.
Disconnect the test mode connector.
Turn the ignition switch to ON.
Measure the voltage between ECM and chassis ground.
Connector & terminal
(B84) No. 17 (+) — Chassis ground (−):
(B84) No. 28 (+) — Chassis ground (−):
Is the voltage more than 10 V?
Yes |
Repair the battery short circuit
in radiator fan relay control circuit. After repair, replace the
ECM.
No |
CHECK MAIN FAN RELAY.
Turn the ignition switch to OFF.Remove the main fan relay.
Measure the resistance between main fan relay terminals.
Terminals
No. 30 — No. 31: (Main fan relay 1)
No. 28 — No. 29: (Main fan relay 2)
Is the resistance less than 1 Ω?
Yes |
Replace the main fan relay and ECM.
No |
CHECK SUB FAN RELAY.
Remove the sub fan relay.Measure the resistance between sub fan relay terminals.
Terminals
No. 8 — No. 9: (Sub fan relay 1)
No. 20 — No. 21: (Sub fan relay 2)
Is the resistance less than 1 Ω?
Yes |
Replace the sub fan relay and ECM.
No |
CHECK POOR CONTACT.
Check poor contact in ECM connector.Is there poor contact in ECM connector?
Yes |
Repair the poor contact in ECM connector.
No |