DTC P0134 O2 SENSOR CIRCUIT NO ACTIVITY DETECTED (BANK 1 SENSOR 1)
 
 
 
  
   
    
     | 
      | 
     
      DTC P0134 O
      
       2
      
      SENSOR CIRCUIT NO
ACTIVITY DETECTED (BANK 1 SENSOR 1)
      | 
    
   
  
  
  
  
  
   CHECK HARNESS BETWEEN ECM AND FRONT OXYGEN (A/F)
SENSOR CONNECTOR.
  
  
   Turn the ignition switch to OFF.
   
   
  
  
   Disconnect the connectors from ECM and front oxygen
(A/F) sensor connector.
   
   
  
  
   Measure the resistance of harness between ECM and front
oxygen (A/F) sensor connector.
   
   
   
    Connector & terminal
   
   
   
   
    (B134) No. 33 — (B18) No. 1:
   
   
   
   
    (B134) No. 26 — (B18) No. 3:
   
   
   
   
    Is the resistance less than 1 Ω?
   
   
   
    
     
    
   
   
   
  
  
  
   
    
     
      | 
       •
       | 
      
       Repair harness and connector.
        
        
       | 
     
    
   
  
  
   
    
     
      | 
       •
       | 
      
       
        
         
          
           | 
            Note
            | 
           
          
           | 
             
             In this case, repair the following:
             
            | 
           
          
           | 
            •
            | 
           
            Open circuit
in harness between ECM and front oxygen (A/F) sensor connector
             
             
            | 
           
          
           | 
            •
            | 
           
            Poor contact in front oxygen (A/F) sensor connector
             
             
            | 
           
          
           | 
            •
            | 
           
            Poor contact in ECM connector
             
             
            | 
           
         
         
         
       
       | 
     
    
   
  
  
  
  
  
   CHECK POOR CONTACT.
  
  
   Check poor contact in front oxygen (A/F) sensor connector.
   
   
   
    Is there poor contact in front oxygen (A/F) sensor
connector?
   
   
   
    Repair poor contact in front oxygen (A/F)
sensor connector.
   
   
   
   
    Replace the front oxygen (A/F)
sensor.