SAAB WIS ONLINE

DTC P0604 INTERNAL CONTROL MODULE RANDOM ACCESS MEMORY (RAM) ERROR

DTC P0604 INTERNAL CONTROL MODULE RANDOM ACCESS MEMORY (RAM) ERROR

DTC DETECTING CONDITION:


Immediately at fault recognition

GENERAL DESCRIPTION


TROUBLE SYMPTOM:


Engine does not start.

Engine stalls.


Important

After repair or replacement of faulty parts, conduct Clear Memory Mode and Inspection Mode .


WIRING DIAGRAM:


CHECK ANY OTHER DTC ON DISPLAY.

Is any other DTC displayed?

Yes

Check the relevant DTC using the List of Diagnostic Trouble Code (DTC).


No

A temporary poor contact occurs.