Cellular Telephone Charging Malfunction
|
Cellular Telephone Charging Malfunction
|
Diagnostic Fault Information
|
Circuit
|
Short to Ground
|
Open/High Resistance
|
Short to Voltage
|
Signal Performance
|
12 V Reference
|
1
|
1
|
-
|
-
|
Cradle Signal 1
|
-
|
-
|
-
|
-
|
Cradle Signal 2
|
-
|
-
|
-
|
-
|
Low Reference
|
-
|
1
|
1
|
-
|
1. Charging Inoperative
|
Circuit/System Description
|
The mobile telephone control module uses the cradle to charge the cellular telephone.
Schematic Reference
Cellular Telephone Schematics
Connector End View Reference
Component Connector End Views
Description and Operation
Cellular Telephone Description and Operation
Electrical Information Reference
Scan Tool Reference
Control Module References
for scan tool information
Circuit/System Verification
|
Ignition ON, connect the cellular phone to the cradle observe the scan tool Phone in Cradle parameter. The reading should be Yes.
Note
|
You must perform the Circuit/System Verification before proceeding with Circuit/System Testing.
|
Connecting Malfunction
1.
|
Ignition OFF, disconnect the X2 connector at the K82 Mobile Telephone Control Module and the X1 connector at the X91 Mobile Telephone Connector.
|
2.
|
Ignition ON, test for less than 0.3 V between the signal circuit terminal 13 X2 at the K82 Mobile Telephone Control Module and ground.
|
3.
|
If greater than the specified range, test the signal circuit terminal 13 X2 at the K82 Mobile Telephone Control Module for a short to voltage.
|
4.
|
Ignition ON, test for less than 0.3 V between the signal circuit terminal 15 X2 at the K82 Mobile Telephone Control Module and ground.
|
5.
|
If greater than the specified range, test the signal circuit terminal 15 X2 at the K82 Mobile Telephone Control Module for a short to voltage.
|
6.
|
Ignition OFF, test for infinite resistance between the signal circuit terminal 13 X2 at the K82 Mobile Telephone Control Module and ground.
|
7.
|
If less than the specified range, test the signal circuit terminal 13 X2 at the K82 Mobile Telephone Control Module for a short to ground.
|
8.
|
Ignition OFF, test for infinite resistance between the signal circuit terminal 15 X2 at the K82 Mobile Telephone Control Module and ground.
|
9.
|
If less than the specified range, test the signal circuit terminal 15 X2 at the K82 Mobile Telephone Control Module for a short to ground.
|
10.
|
Ignition OFF, test for less than 5 Ω between the signal circuit terminal 13 X2 at the K82 Mobile Telephone Control Module and the signal circuit terminal 10 X1 at the X91 Mobile Telephone Connector.
|
11.
|
If less than the specified range, test the signal circuit terminal 13 X2 at the K82 Mobile Telephone Control Module for an open/high resistance.
|
12.
|
Ignition OFF, test for less than 5 Ω between the signal circuit terminal 15 X2 at the K82 Mobile Telephone Control Module and the signal circuit terminal 2 X1 at the X91 Mobile Telephone Connector.
|
13.
|
If less than the specified range, test the signal circuit terminal 15 X2 at the K82 Mobile Telephone Control Module for an open/high resistance.
|
14.
|
If all circuits test normal, replace the X91 Mobile Telephone Connector and verify that the customer concern is not still present.
|
15.
|
If the customer concern is still present, replace the K82 Mobile Telephone Control Module.
|
Charging Inoperative
1.
|
Ignition OFF, disconnect the X1 and X2 connector at the K82 Mobile Telephone Control Module.
|
2.
|
Ignition OFF, test for less than 5 Ω between the low reference circuit terminal 2 X1 and ground.
|
3.
|
If greater than the specified range, test the low reference circuit for an open/high resistance. If the circuit tests normal, replace the K82 mobile telephone control module.
|
4.
|
Ignition ON, test for greater than 11 V between the 12 V reference circuit terminal 1 X1 and ground.
|
5.
|
If less than the specified range, test the 12 V reference circuit for a short to ground or an open/high resistance. If the circuit tests normal, replace the K82 mobile telephone control module.
|
6.
|
Ignition ON, test for less than 0.3 V between the low reference circuit terminal 8 X2 at the K82 Mobile Telephone Control Module and ground.
|
7.
|
If greater than the specified range, test the low reference circuit terminal 8 X2 at the K82 Mobile Telephone Control Module for a short to voltage.
|
8.
|
Ignition ON, test for less than 0.3 V between the signal circuit terminal 16 X2 at the K82 Mobile Telephone Control Module and ground.
|
9.
|
If greater than the specified range, test the signal circuit terminal 16 X2 at the K82 Mobile Telephone Control Module for a short to voltage.
|
10.
|
Ignition OFF, test for infinite resistance between the low reference circuit terminal 8 X2 at the K82 Mobile Telephone Control Module and ground.
|
11.
|
If less than the specified range, test the low reference circuit terminal 8 X2 at the K82 Mobile Telephone Control Module for a short to ground.
|
12.
|
Ignition OFF, test for infinite resistance between the signal circuit terminal 16 X2 at the K82 Mobile Telephone Control Module and ground.
|
13.
|
If less than the specified range, test the signal circuit terminal 16 X2 at the K82 Mobile Telephone Control Module for a short to ground.
|
14.
|
Ignition OFF, test for less than 5 Ω between the signal circuit terminal 8 X2 at the K82 Mobile Telephone Control Module and the signal circuit terminal 4 X1 at the X91 Mobile Telephone Connector.
|
15.
|
If less than the specified range, test the signal circuit terminal 8 X2 at the K82 Mobile Telephone Control Module for an open/high resistance.
|
16.
|
Ignition OFF, test for less than 5 Ω between the signal circuit terminal 16 X2 at the K82 Mobile Telephone Control Module and the signal circuit terminal 8 X1 at the X91 Mobile Telephone Connector.
|
17.
|
If less than the specified range, test the signal circuit terminal 16 X2 at the K82 Mobile Telephone Control Module for an open/high resistance.
|
18.
|
If all circuits test normal, replace the X91 Mobile Telephone Connector and verify that the customer concern is not still present.
|
19.
|
If the customer concern is still present, replace the K82 Mobile Telephone Control Module.
|
Perform the
Diagnostic Repair Verification
after completing the diagnostic procedure.
Control Module References
for remote control door lock receiver replacement, setup, and programming