Brake Booster Pump Motor Malfunction
|
Brake Booster Pump Motor Malfunction
|
Diagnostic Fault Information
|
Circuit
|
Short to Ground
|
Open/High Resistance
|
Short to Voltage
|
Signal Performance
|
Brake Booster Pump Motor B+
|
1
|
1
|
-
|
-
|
Brake Booster Vacuum Sensor Ignition
|
1
|
1
|
-
|
-
|
Brake Booster Pump Control
|
1
|
1
|
2
|
-
|
Brake Booster Pump Ground
|
-
|
1
|
1
|
-
|
1. Brake Booster Pump Always Off
2. Brake Booster Pump Always On
|
Circuit/System Description
|
The brake booster vacuum switch monitors the amount of vacuum available to the power brake booster. When the vacuum within the system drops, the switch within the brake booster vacuum sensor closes allowing voltage to be supplied to the brake booster pump motor.
Connector End View Reference
Component Connector End Views
Description and Operation
Brake Booster Vacuum Assist Description and Operation
Electrical Information Reference
1.
|
Ignition OFF, disconnect the harness connector at the M9 brake booster pump.
|
2.
|
Test for less than 1 Ω between the ground circuit terminal 1 and ground.
|
3.
|
If greater than the specified range, test the ground circuit for an open/high resistance.
|
4.
|
Ignition ON, verify that a test lamp illuminates between the B+ circuit terminal 5 and ground.
|
5.
|
If the test lamp does not illuminate, test the B+ circuit for a short to ground or an open/high resistance. If the circuit tests normal and the B+ circuit fuse is open, test or replace the M9 brake booster pump motor.
|
6.
|
Ignition OFF, connect the harness connector at the M9 brake booster pump motor and disconnect the harness connector at the B19B brake booster vacuum sensor.
|
7.
|
Ignition ON, verify that a test lamp illuminates between the ignition circuit terminal 1 and ground.
|
8.
|
If the test lamp does not illuminate, test the ignition circuit terminal for a short to ground or an open/high resistance.
|
9.
|
Verify that a test lamp does not illuminate between the control circuit terminal 2 and ground.
|
10.
|
If the test lamp illuminates, test the control circuit for a short to voltage.
|
11.
|
Connect a 10 A fused jumper wire between the ignition circuit terminal 1 and the control circuit terminal 2. Verify the M9 brake booster pump motor activates.
|
12.
|
If the M9 brake booster pump motor is not active, test the control circuit terminal 2 for a short to ground or an open/high resistance. If the circuit tests normal, test or replace the M9 brake booster pump motor.
|
13.
|
If all circuits test normal, test or replace the B19B brake booster vacuum sensor.
|
Brake Booster Pump Motor
1.
|
Ignition OFF, disconnect the harness connector at the M9 brake booster pump motor
|
2.
|
Connect a 20 A fused jumper wire between the B+ terminal 5 and B+.
|
3.
|
Connect a 10 A fused jumper wire between the control terminal 2 and B+
|
4.
|
Connect a jumper wire between the ground terminal 1 and ground, verify the M9 brake booster pump motor activates.
|
5.
|
If the M9 brake booster pump motor does not activate, replace the M9 brake booster pump motor.
|
Perform the
Diagnostic Repair Verification
after completing the diagnostic procedure.
Power Brake Booster Pump Replacement (LDK/A20NHT)
Power Brake Booster Pump Replacement (LAU/A28NER)