SAAB WIS ONLINE

Air Bag Indicator Circuit Malfunction (Driver)

Air Bag Indicator Circuit Malfunction (Driver)

Diagnostic Instructions


Perform the Diagnostic System Check - Vehicle prior to using this diagnostic procedure.

Review Strategy Based Diagnosis for an overview of the diagnostic approach.

Diagnostic Procedure Instructions provides an overview of each diagnostic category.


Circuit/System Description

When the ignition is turned ON, during the bulb check, the driver air bag indicator will flash, and then turn OFF after the bulb check. The inflatable restraint sensing and diagnostic module (SDM) performs diagnostic tests on the SIR system during the bulb check. If any malfunction exists the SDM will request the instrument cluster to illuminate the air bag indicator steady, via serial data. If a preexisting malfunction exists, the air bag indicator will illuminate steady immediately after the ignition is turned ON. If the ignition 1 voltage is outside of the normal operating voltage range of 9-16 V, the SDM will command the instrument cluster to illuminate the air bag indicator ON, even with no DTCs present, and then disable all deployment loops.

Diagnostic Aids

A DTC B1370 may set if the ignition 1 circuit is outside the 9-16 V range.

Reference Information

Schematic Reference

SIR Schematics

Connector End View Reference

Component Connector End Views

Description and Operation

SIR System Description and Operation

Electrical Information Reference


Circuit Testing

Testing for Intermittent Conditions and Poor Connections

Connector Repairs

Wiring Repairs


Scan Tool Reference

Control Module References for scan tool information

Circuit/System Testing


1. Verify SDM DTCs are not set.

2. If any DTCs are set, refer to Diagnostic Trouble Code (DTC) List - Vehicle .

3. With a scan tool command the Instrument Cluster to turn all instrument cluster indicators ON and OFF. The air bag indicators should turn ON and OFF as commanded.

4. If the air bag indicator does not turn ON and OFF as expected, replace the P16 instrument cluster.

5. If all circuits test normal, replace the K36 SDM.


Repair Instructions

Perform the Diagnostic Repair Verification after completing the diagnostic procedure.


SIR/SRS Wiring Repairs

Control Module References for instrument cluster and SDM replacement, setup, and programming