DTC B018A, B048C, B048F, or B1395
|
DTC B018A, B048C, B048F, or B1395
|
DTC B018A 02
Windshield Temperature Sensor Circuit Short to Ground
DTC B018A 05
Windshield Temperature Sensor Circuit High Voltage/Open
DTC B048C 02
Humidity Sensor Humidity Circuit Short to Ground
DTC B048C 05
Humidity Sensor Humidity Circuit High Voltage/Open
DTC B048F 02
Humidity Sensor Temperature Circuit Short to Ground
DTC B048F 05
Humidity Sensor Temperature Circuit High Voltage/Open
DTC B1395 03
Control Module Voltage Reference Output Circuit Low Voltage
DTC B1395 07
Control Module Voltage Reference Output Circuit High Voltage
Diagnostic Fault Information
|
Circuit
|
Short to Ground
|
Open/High Resistance
|
Short to Voltage
|
Signal Performance
|
Windshield Temperature and Inside Moisture Sensor 5V Reference
|
B1395 03
|
-
|
B1395 07
|
-
|
Humidity Signal
|
B048C 02
|
B048C 05
|
B048C 05
|
-
|
Humidity Temperature Signal
|
B048F 02
|
B048F 05
|
B048F 05
|
-
|
Windshield Temperature Signal
|
B018A 02
|
B018A 05
|
B018A 05
|
-
|
Windshield Temperature and Inside Moisture Sensor Ground
|
-
|
B018A 05,
B048C 05,
B048F 05,
|
-
|
-
|
Circuit/System Description
|
The windshield temperature and inside moisture sensor includes the relative humidity sensor, windshield temperature sensor and humidity sensing element temperature sensor.
This sensor assembly provides information about:
•
|
Relative humidity level at windshield inside
|
•
|
Temperature of the windshield inside
|
•
|
Temperature of the humidity sensor element
|
The relative humidity sensor measures the relative humidity of the compartment side of the windshield. It also detects the temperature of the windshield surface on the compartment side. Both values are used as control inputs for the HVAC control module application to calculate the fog risk on windshield compartment side and ability to reduce fuel consumption by decreasing A/C compressor power to a minimum without causing any fog. The sensor will also enable partial recirculation mode in order to improve heat-up performance of the passenger compartment under cold ambient temperature conditions without the risk of mist build-up on the windshield. The humidity sensor element temperature sensor supplies the temperature of the humidity sensor element. It is only needed if the thermal contact between the humidity sensing element and the inside windshield surface is not sufficient.
Conditions for Running the DTC
|
•
|
The HVAC control module is ON.
|
Conditions for Setting the DTC
|
B018A 02, B048C 02, B048C 02 or B1395 03
The HVAC control module detects the sensor signal out of range. The signal voltage is less than 0.1 V for more than 50 ms.
B018A 05, B048C 05, B048C 05 or B1395 07
The HVAC control module detects the sensor signal out of range. The signal voltage is greater than 4.9 V for more than 50 ms.
Action Taken When the DTC Sets
|
•
|
The system will use the last valid values as default.
|
•
|
If no value is read at the time of fault, the HVAC control module uses 60% for humidity.
|
Conditions for Clearing the DTC
|
The condition for setting the DTC is no longer present.
Schematic Reference
HVAC Schematics
Connector End View Reference
Component Connector End Views
Description and Operation
Automatic HVAC Description and Operation
Electrical Information Reference
Scan Tool Reference
Control Module References
Circuit/System Verification
|
1.
|
Verify that DTC B1395 03 or B1395 07 is not present.
|
2.
|
If DTC is present, refer to Windshield Temperature And Inside Moisture Sensor Power Supply Malfunction.
|
3.
|
Verify that DTC B048C 02 or B048C 05 is not present.
|
4.
|
If DTC is present, refer to Humidity Sensor Humidity Circuit Malfunction.
|
5.
|
Verify that DTC B048F 02 or B048F 05 is not present.
|
6.
|
If DTC is present, refer to Humidity Sensor Temperature Circuit Malfunction.
|
7.
|
Verify that DTC B018A 02 or B018A 05 is not present.
|
8.
|
If DTC is present, refer to Windshield Temperature Sensor Circuit Malfunction.
|
9.
|
Measure actual temperature using a thermometer at the windshield temperature and inside moisture sensor. Compare this value to the scan tool Passenger Compartment Humidity Sensor Temperature parameter. The measured temperature should be within 5°C (9°F) difference of parameter value.
|
10.
|
If not within the specified range, replace the B160 Windshield Temperature and Inside Moisture Sensor.
|
11.
|
Measure actual temperature using a thermometer at the windshield temperature and inside moisture sensor. Compare this value to the scan tool Windshield Temperature parameter. The measured temperature should be within 5°C (9°F) difference of parameter value.
|
12.
|
If not within the specified range, replace the B160 Windshield Temperature and Inside Moisture Sensor.
|
Windshield Temperature and Inside Moisture Sensor Power Supply Malfunction
1.
|
Ignition OFF, disconnect the harness connector at the B160 Windshield Temperature and Inside Moisture Sensor.
|
2.
|
Test for less than 5 Ω between the ground circuit terminal 3 and ground.
|
3.
|
If greater than the specified range, test the ground circuit for an open/high resistance.
|
4.
|
Ignition ON, test for 4.8-5.2 V between the ground circuit terminal 3 and the reference voltage circuit terminal 1.
|
5.
|
If less than the specified range, test the reference voltage circuit for a short to ground or open/high resistance. If the circuit tests normal, replace the K33 HVAC control module.
|
6.
|
If greater than the specified range, test the reference voltage circuit for a short to voltage. If the circuit tests normal, replace the K33 HVAC control module.
|
7.
|
If all circuits test normal, replace the B160 Windshield Temperature and Inside Moisture Sensor.
|
Humidity Sensor Humidity Circuit Malfunction
1.
|
Ignition OFF, disconnect the harness connector at the B160 Windshield Temperature and Inside Moisture Sensor.
|
2.
|
Test for less than 5 Ω between the ground circuit terminal 3 and ground.
|
3.
|
If greater than the specified range, test the ground circuit for an open/high resistance.
|
4.
|
Ignition ON, test for 4.8-5.2 V between the ground circuit terminal 3 and the reference voltage circuit terminal 1.
|
5.
|
If less than the specified range, test the reference voltage circuit for an open/high resistance. If the circuit tests normal, replace the K33 HVAC control module.
|
6.
|
Test for 4.8-5.2 V between the signal circuit terminal 2 and ground.
|
7.
|
If less than the specified range, test the signal circuit terminal for a short to ground or open/high resistance . If the circuit tests normal, replace the K33 HVAC control module.
|
8.
|
If greater than the specified range, test the signal circuit terminal for a short to battery. If the circuit tests normal, replace the K33 HVAC control module.
|
9.
|
If all circuits test normal, replace the B160 Windshield Temperature and Inside Moisture Sensor and verify the DTC does not reset.
|
10.
|
If the DTC resets, replace the K33 HVAC Control Module.
|
Humidity Sensor Temperature Circuit Malfunction
1.
|
Ignition OFF, disconnect the harness connector at the B160 Windshield Temperature and Inside Moisture Sensor.
|
2.
|
Ignition ON, test for 4.8-5.2 V between the signal circuit terminal 5 and ground.
|
3.
|
If less than the specified range, test the signal circuit terminal for a short to ground or open/high resistance . If the circuit tests normal, replace the K33 HVAC control module.
|
4.
|
If greater than the specified range, test the signal circuit terminal for a short to battery. If the circuit tests normal, replace the K33 HVAC control module.
|
5.
|
If all circuits test normal, replace the B160 Windshield Temperature and Inside Moisture Sensor and verify the DTC does not reset.
|
6.
|
If the DTC resets, replace the K33 HVAC Control Module.
|
Windshield Temperature Sensor Circuit Malfunction
1.
|
Ignition OFF, disconnect the harness connector at the B160 Windshield Temperature and Inside Moisture Sensor.
|
2.
|
Ignition ON, test for 4.8-5.2 V between the signal circuit terminal 4 and ground.
|
3.
|
If less than the specified range, test the signal circuit terminal for a short to ground or open/high resistance . If the circuit tests normal, replace the K33 HVAC control module.
|
4.
|
If greater than the specified range, test the signal circuit terminal for a short to battery. If the circuit tests normal, replace the K33 HVAC control module.
|
5.
|
If all circuits test normal, replace the B160 Windshield Temperature and Inside Moisture Sensor and verify the DTC does not reset.
|
6.
|
If the DTC resets, replace the K33 HVAC Control Module.
|
Perform the
Diagnostic Repair Verification
after completing the diagnostic procedure.