DTC B0208
DTC B0208 |
Diagnostic Instructions |
• |
Perform the
Diagnostic System Check - Vehicle
prior to using this diagnostic procedure.
|
• |
Review
Strategy Based Diagnosis
for an overview of the diagnostic approach.
|
• |
Diagnostic Procedure Instructions
provides an overview of each diagnostic category.
|
DTC Descriptors |
DTC B0208 01
Rear Blower Motor Speed Circuit Short to Battery
DTC B0208 06
Rear Blower Motor Speed Circuit Low Voltage/Open
Diagnostic Fault Information |
Circuit | Short to Ground | Open/High Resistance | Short to Voltage | Signal Performance |
Rear Blower Motor Control Module B+
|
B0208 06
|
B0208 06
|
-
|
-
|
Rear Blower Motor Control Module Control
|
B0208 06
|
B0208 06
|
B0208 01
|
-
|
Rear Blower Motor Control Module Ground
|
-
|
-
|
-
|
-
|
Circuit/System Description |
The Blower Motor Control Module - Auxiliary is an interface between the HVAC Control Module and the Blower Motor. The Blower Motor Speed Control from the HVAC Control Module, battery positive and ground circuits enable the Blower Motor Control Module - Auxiliary to operate. The HVAC Control Module provides a Pulse Width Modulation (PWM) signal to the Blower Motor Control Module - Auxiliary in order to command the blower motor speed. The Blower Motor Control Module - Auxiliary transfers the PWM signal into a corresponding blower motor voltage. The voltage resides between 2-13 V and changes linear to the height of the PWM signal.
Conditions for Running the DTC |
• |
Ignition ON.
|
• |
The HVAC control module is ON.
|
Conditions for Setting the DTC |
B0208 01
The voltage at the HVAC Control Module output to the Blower Motor Control Module - Auxiliary is always high.B0208 06
The voltage at the HVAC Control Module output to the Blower Motor Control Module - Auxiliary is always low or floating.Action Taken When the DTC Sets |
The blower motor is inoperative.
Conditions for Clearing the DTC |
The condition for setting the DTC is no longer present.
Reference Information |
Schematic Reference
HVAC Schematics
Connector End View Reference
Component Connector End Views
Description and Operation
Automatic HVAC Description and Operation
Electrical Information Reference
• |
Circuit Testing
|
• |
Connector Repairs
|
• |
Testing for Intermittent Conditions and Poor Connections
|
• |
Wiring Repairs
|
Scan Tool Reference
Control Module References for scan tool information
Circuit/System Testing |
1. |
Ignition OFF, disconnect the X2 harness connector at the K33 HVAC Control Module and the X1 harness connector at the K8A Blower Motor Control Module - Auxiliary.
|
2. |
Verify that a test lamp illuminates between the K8A Blower Motor Control Module - Auxiliary ground circuit terminal 4 X1 and B+.
|
3. |
If the test lamp does not illuminate, test the ground circuit for an open circuit/high resistance.
|
4. |
Ignition ON, verify that a test lamp illuminates between the B+ circuit terminal 2 X1 at the K8A Blower Motor Control Module - Auxiliary harness connector and ground.
|
5. |
If the test lamp does not illuminate, test the B+ circuit for a short to ground or an open/high resistance.
|
6. |
Test for less than 0.3 V between the control circuit terminal 1 X1 at the K8A Blower Motor Control Module - Auxiliary harness connector and ground.
|
7. |
If greater than the specified value, test the control circuit for a short to voltage.
|
8. |
Ignition OFF, test for infinite resistance between the control circuit terminal 1 X1 at the K8A Blower Motor Control Module - Auxiliary harness connector and ground.
|
9. |
If less than the specified value, test the control circuit for a short to ground.
|
10. |
Test for less than 5 Ω between the K33 HVAC Control Module control circuit terminal 16 X2 and control circuit terminal 1 X1 at the K8A Blower Motor Control Module - Auxiliary harness connector.
|
11. |
If greater than the specified value, test the control circuit for an open/high resistance.
|
12. |
If all circuits test normal, replace the K8A Blower Motor Control Module - Auxiliary and verify the DTC does not reset.
|
13. |
If the DTC resets, replace the K33 HVAC Control Module.
|
Repair Instructions |
Perform the Diagnostic Repair Verification after completing the diagnostic procedure.
• |
TBD Link 63259 [Auxiliary Heater and Air Conditioning Control Module Replacement ]
|
• |
Control Module References