Air Temperature Malfunction
Air Temperature Malfunction |
Diagnostic Instructions |
• |
Perform the
Diagnostic System Check - Vehicle
prior to using this diagnostic procedure.
|
• |
Review
Strategy Based Diagnosis
for an overview of the diagnostic approach.
|
• |
Diagnostic Procedure Instructions
provides an overview of each diagnostic category.
|
Diagnostic Fault Information |
Circuit | Short to Ground | Open/High Resistance | Short to Voltage | Signal Performance |
Stepper Motors 12V Reference
|
B023A 02, B0223 06, B022A 06, B0233 06, B0408 06, B0418 06
|
B0223 06, B022A 06, B0233 06, B0408 06, B0418 06
|
-
|
-
|
Air Temperature Actuator - Left Control 1
|
B0408 06
|
B0408 06
|
B0408 01
|
1
|
Air Temperature Actuator - Left Control 2
|
B0408 06
|
B0408 06
|
B0408 01
|
1
|
Air Temperature Actuator - Left Control 3
|
B0408 06
|
B0408 06
|
B0408 01
|
1
|
Air Temperature Actuator - Left Control 4
|
B0408 06
|
B0408 06
|
B0408 01
|
1
|
Air Temperature Actuator - Right Control 1
|
B0418 06
|
B0418 06
|
B0418 01
|
1
|
Air Temperature Actuator - Right Control 2
|
B0418 06
|
B0418 06
|
B0418 01
|
1
|
Air Temperature Actuator - Right Control 3
|
B0418 06
|
B0418 06
|
B0418 01
|
1
|
Air Temperature Actuator - Right Control 4
|
B0418 06
|
B0418 06
|
B0418 01
|
1
|
1. Air Temperature Malfunction
|
Circuit/System Description |
With the temperature switches at the Radio/HVAC control, the wished air temperature flap position can be put in. The selected values are sent to the HVAC control module via LIN-Bus. The HVAC control module supplies a 12 V reference voltage to the stepper motors and energizes the 4 stepper motor coils with a pulsed ground signal. The stepper motors put the mixed air flaps into the calculated position, in order to reach the put in temperature.
Diagnostic Aids |
Check the following mechanical fault sources:
• |
Air distribution box
|
• |
Air distribution hoses/air distribution ducts
|
Reference Information |
Schematic Reference
HVAC Schematics
Connector End View Reference
Component Connector End Views
Description and Operation
Automatic HVAC Description and Operation
Electrical Information Reference
• |
Circuit Testing
|
• |
Connector Repairs
|
• |
Testing for Intermittent Conditions and Poor Connections
|
• |
Wiring Repairs
|
Scan Tool Reference
Control Module References for scan tool information
Circuit/System Verification |
1. |
Ignition ON, measure actual inside air temperature using a thermometer. Compare this value to the scan tool Passenger Compartment Air Temperature parameter. The measured temperature should be within 5°C (9°F) difference of parameter value.
|
2. |
If not within the specified range, refer to
DTC B0163, B0183, or B1405
.
|
3. |
Measure actual temperature using a thermometer at each of the duct temperature sensors. Compare this value to the appropriate scan tool Duct Actual parameter. The measured temperature should be within 5°C (9°F) difference of appropriate Duct Actual parameter value.
|
4. |
If not within the specified range, refer to
DTC B0173, B0178, B0509, B0514, B0519, B3583, or B3933
.
|
5. |
Measure actual evaporator temperature using a thermometer. Compare this value to the scan tool A/C Evaporator Temperature Sensor parameter. The measured temperature should be within 5°C (9°F) difference of parameter value.
|
6. |
If not within the specified range, refer to
DTC B0173, B0178, B0509, B0514, B0519, B3583, or B3933
.
|
7. |
Observe the scan tool Sunload parameter. The reading should be between 50-1 150 W/m
2
and change with sunlight intensity.
|
8. |
If not within the specified range or not change, refer to
DTC B0163, B0183, or B1405
.
|
9. |
Engine is running, activate and deactivate the A/C switch. Verify the A/C compressor can be activated and deactivated.
|
10. |
If the A/C compressor cannot be activated or deactivated, refer to
Air Conditioning Compressor Malfunction
.
|
11. |
Verify the engine reaches its operating temperature.
|
Circuit/System Testing |
1. |
Ignition ON, turn the left temperature knob in all positions. Verify the scan tool Left Temperature Knob Position parameter. The reading should correspond to the selected temperature.
|
2. |
If not the specified value, replace the A20 Radio/HVAC Controls.
|
3. |
Ignition ON, turn the right temperature knob in all positions. Verify the scan tool Right Temperature Knob Position parameter. The reading should correspond to the selected temperature.
|
4. |
If not the specified value, replace the A20 Radio/HVAC Controls.
|
5. |
Press and release the AUTO Switch. Verify the scan tool Auto HVAC Button parameter changes between Active and Inactive.
|
6. |
If not the specified value, replace the A20 Radio/HVAC Controls.
|
7. |
Press and release the ZONE Switch. Verify the scan tool MULTI-ZONE Switch parameter changes between Active and Inactive.
|
8. |
If not the specified value, replace the A20 Radio/HVAC Controls.
|
9. |
Verify the M6L Air Temperature Door Actuator - Left can be put into all positions.
|
10. |
If the M6L Air Temperature Door Actuator - Left cannot be put into all positions, replace the M6L Air Temperature Door Actuator - Left and verify the M6L Air Temperature Door Actuator - Left can be put into all positions. If the M6L Air Temperature Door Actuator - Left cannot be put into all positions, replace the K33 HVAC Control Module.
|
11. |
If all circuits test normal, replace the M6R Air Temperature Door Actuator - Right and verify the M6R Air Temperature Door Actuator - Right can be put into all positions. If the M6R Air Temperature Door Actuator - Right cannot be put into all positions, replace the K33 HVAC Control Module.
|
Repair Instructions |
Perform the Diagnostic Repair Verification after completing the diagnostic procedure.
• |
Temperature Valve Actuator Replacement - Left Side (Left Hand Drive)
Temperature Valve Actuator Replacement - Left Side (Right Hand Drive)
|
• |
Temperature Valve Actuator Replacement - Right Side (Left Hand Drive)
|
• |
Instrument Panel Lower Center Trim Panel Replacement
|
• |
Control Module References
for HVAC control module replacement, setup, and programming
|