Water Pump Replacement (LHU/A20NFT)
Water Pump Replacement (LHU/A20NFT) |
Special Tools
EN-44602 Water Pump HolderFor equivalent regional tools, refer to Special Tools .
Removal Procedure |
2. |
Remove the radiator outlet pipe. Refer to
Radiator Outlet Pipe Replacement
.
|
3. |
Remove the water pump cover. Refer to
Water Pump Cover Replacement
.
|
4. |
Install the EN-44602 water pump holder (1). |
• |
Tighten the
EN-44602
water pump holder and rotate clockwise to tighten the water pump and balancer chain.
|
• |
Fix with
EN-44602
water pump holder (1) the water pump sprocket (2).
|
5. |
Remove the 3 fasteners (1) from the water pump chain sprocket.
|
6. |
Remove the 4 fasteners (1) from the water pump.
|
Installation Procedure |
1. |
Refer to
Fastener Caution
.
Install the water pump and tighten the fasteners (1) to 23Nm (17 lb ft) . |
2. |
Install the water pump sprocket and tighten the fasteners (1) to
8 Nm (71 lb in)
.
|
3. |
Remove the
EN-44602
water pump holder (1).
|
4. |
Install the water pump cover. Refer to
Water Pump Cover Replacement
.
|
5. |
Install the radiator outlet pipe. Refer to
Radiator Outlet Pipe Replacement
.
|