SAAB WIS ONLINE

Diagnostic trouble code table

Diagnostic trouble code table

Diagnostic trouble code Display Defective function/component Malfunction Test frequency Diagnostic procedure, see page
B1340

03

Solar sensor

Open circuit or communication error

With 2.5 Hz



B1345

04

Mixed-air temperature sensor, LH

Open circuit or short to B+

With 2.5 Hz



B1345

04

Mixed-air temperature sensor, LH

Short-circuit to ground

With 2.5 Hz



B1350

02

Cabin temperature sensor

Open circuit or short to B+

With 2.5 Hz



B1350

02

Cabin temperature sensor

Short-circuit to ground

With 2.5 Hz



B1605

01

Control module

Internal control module malfunction

With ignition ON



B2290

09

Stepping motor, air-mixing flap, RH

Open circuit

Continuously



B2290

09

Stepping motor, air-mixing flap, RH

Short-circuit to ground

Continuously



B2295

08

Stepping motor, air-mixing flap, RH

Loose flap

Continuously



B2296

10

Stepping motor, air-mixing flap, RH

Jammed flap

Continuously



B2345

05

Mixed-air temperature sensor, RH

Short-circuit to ground

With 2.5 Hz



B2345

05

Mixed-air temperature sensor, RH

Open circuit or short to B+

With 2.5 Hz



B2375

18

Heat exchanger solenoid

Open circuit, short-circuit to ground

With 2.5 Hz



B2375

18

Heat exchanger solenoid

Short-circuit to B+

With 2.5 Hz



B2380

19

Circulation pump

Open circuit, short-circuit to ground

With 2.5 Hz



B2380

19

Circulation pump

Short-circuit to B+

With 2.5 Hz



B2400

12

Stepping motor, air distribution flap

Open circuit

Continuously



B2400

12

Stepping motor, air distribution flap

Short-circuit to ground

Continuously



B2405

14

Stepping motor, air distribution flap

Loose flap

Continuously



B2406

13

Stepping motor, air distribution flap

Jammed flap

Continuously



B2410

21

Direct current motor, air recirculation flap

B+ open circuit or shorted to ground

With 2.5 Hz



B2425

20

Control voltage, fan

Short-circuit to B+

Continuously



B2425

20

Control voltage, fan

Short-circuit to ground

Continuously



B2490

06

Stepping motor, air-mixing flap, LH

Open circuit, short to B+ or short to ground

Continuously



B2495

08

Stepping motor, air-mixing flap, LH

Loose flap

Continuously



B2496

07

Stepping motor, air-mixing flap, LH

Jammed flap

Continuously



B2945

23

Sensor ground

Ground to sensors shorting to B+

At 2.5 Hz